Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 318
Filtrar
1.
Sensors (Basel) ; 24(6)2024 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-38544023

RESUMO

The Jones matrix and the Mueller matrix of the coherent Rayleigh backscattering (RB) in single-mode fibers (SMFs) have been derived recently. It has been shown that both matrices depict two polarization effects-birefringence and polarization-dependent loss (PDL)-although the SMF under investigation is purely birefringent, having no PDL. In this paper, we aim to perform a theoretical analysis of both matrices using polar decomposition. The derived sub-Jones/Mueller matrices, representing birefringence and PDL, respectively, can be used to investigate the polarization properties of the coherent RB. As an application of the theoretical results, we use the derived formulas to investigate the polarization properties of the optical signals in phase-sensitive optical time-domain reflectometry (φ-OTDR). For the first time, to our knowledge, by using the derived birefringence-Jones matrix, the common optical phase of the optical signal in φ-OTDR is obtained as the function of the forward phase and birefringence distributions. By using the derived PDL-Mueller matrix, the optical intensity of the optical signal in φ-OTDR is obtained as the function of the forward phase and birefringence distributions as well as the input state of polarization (SOP). Further theoretical predictions show that, in φ-OTDR, the common optical phase depends on only the local birefringence in the first half of the fiber section, which is occupied by the sensing pulse, irrelevant of the input SOP. However, the intensity of the φ-OTDR signal is not a local parameter, which depends on the input SOP and the birefringence distribution along the entire fiber section before the optical pulse. Moreover, the PDL measured in φ-OTDR is theoretically proven to be a local parameter, which is determined by the local birefringence and local optical phase distributions.

2.
J Biomed Opt ; 29(3): 036501, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38487259

RESUMO

Significance: Label-free nonlinear optical microscopy has become a powerful tool for biomedical research. However, the possible photodamage risk hinders further clinical applications. Aim: To reduce these adverse effects, we constructed a new platform of simultaneous label-free autofluorescence multi-harmonic (SLAM) microscopy, featuring four-channel multimodal imaging, inline photodamage monitoring, and pulse repetition-rate tuning. Approach: Using a large-core birefringent photonic crystal fiber for spectral broadening and a prism compressor for pulse pre-chirping, this system allows users to independently adjust pulse width, repetition rate, and energy, which is useful for optimizing imaging conditions towards no/minimal photodamage. Results: It demonstrates label-free multichannel imaging at one excitation pulse per image pixel and thus paves the way for improving the imaging speed by a faster optical scanner with a low risk of nonlinear photodamage. Moreover, the system grants users the flexibility to autonomously fine-tune repetition rate, pulse width, and average power, free from interference, ensuring the discovery of optimal imaging conditions with high SNR and minimal phototoxicity across various applications. Conclusions: The combination of a stable laser source, independently tunable ultrashort pulse, photodamage monitoring features, and a compact design makes this new system a robust, powerful, and user-friendly imaging platform.


Assuntos
Lasers , Fótons , Microscopia Óptica não Linear , Microscopia de Fluorescência por Excitação Multifotônica/métodos
3.
ACS Appl Mater Interfaces ; 16(10): 13071-13081, 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38431899

RESUMO

This study reports for the first time, to the best of our knowledge, a real-time detection of ultralow-concentration chemical gases using fiber-optic technology, combining a miniaturized Fabry-Perot interferometer (FPI) with metal-organic frameworks (MOFs). The sensor consists of a short and thick-walled silica capillary segment spliced to a lead-in single-mode fiber (SMF), housing a tiny single crystal of HKUST-1 MOF, imparting chemoselectivity features. Ethanol and benzene gases were tested, resulting in a shift in the FPI interference signal. The sensor demonstrated high sensitivity, detecting ethanol gas concentrations (EGCs) with a sensitivity of 0.428 nm/ppm between 24.9 and 40.11 ppm and benzene gas concentrations (BGCs) with a sensitivity of 0.15 nm/ppm between 99 and 124 ppm. The selectivity study involved a combination of three ultralow concentrations of ethanol, benzene, and toluene gases, revealing an enhancement factor of 436% for benzene and 140% for toluene, attributed to the improved miscibility of these conjugated ring molecules with the alkane chains of the ethanol-modified HKUST-1. Experimental tests confirmed the sensor's viability, demonstrating significantly improved response time and spectral characteristics through crystal polishing, indicating its potential for quantifying and detecting chemical gases at ultralow concentrations. This technology may prevent energy resource losses, and the sensor's small size and robust construction make it applicable in confined and hazardous locations.

4.
Sensors (Basel) ; 24(3)2024 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-38339446

RESUMO

We demonstrate a sensing scheme for liquid analytes that integrates multiple optical fiber sensors in a near-infrared spectrometer. With a simple optofluidic method, a broadband radiation is encoded in a time-domain interferogram and distributed to different sensing units that interrogate the sample simultaneously; the spectral readout of each unit is extracted from its output signal by a Fourier transform routine. The proposed method allows performing a multiparametric analysis of liquid samples in a compact setup where the radiation source, measurement units, and spectral readout are all integrated in a robust telecom optical fiber. An experimental validation is provided by combining a plasmonic nanostructured fiber probe and a transmission cuvette in the setup and demonstrating the simultaneous measurement of the absorption spectrum and the refractive index of water-methanol solutions.

5.
Bioengineering (Basel) ; 11(1)2024 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-38247938

RESUMO

Diffuse Reflectance Spectroscopy (DRS) can provide tissue feedback for pedicle screw placement in spine surgery, yet the integration of fiber optics into the tip of the pedicle probe, a device used to pierce through bone, is challenging, since the optical probing depth and signal-to-noise ratio (SNR) are affected negatively compared to those of a blunt DRS probe. Through Monte Carlo simulations and optical phantom experiments, we show how differences in the shape of the instrument tip influence the acquired spectrum. Our findings demonstrate that a single bevel with an angle of 30∘ offers a solution to anticipate cortical breaches during pedicle screw placement. Compared to a blunt probe, the optical probing depth and SNR of a cone tip are reduced by 50%. The single bevel tip excels with 75% of the optical probing depth and a SNR remaining at approximately ⅔, facilitating the construction of a surgical instrument with integrated DRS.

6.
Water Res ; 250: 121069, 2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-38150859

RESUMO

Wastewater discharge from outfall pipes can significantly impact river water quality and aquatic ecosystems. Effective outfall monitoring is critical for controlling pollution and protecting public health. This study demonstrates a novel distributed acoustic sensing (DAS) approach for detecting wastewater discharge events from outfall pipes located along rivers. Controlled field experiments were conducted in an industrial park river to systematically evaluate DAS performance. DAS detects vibrational signals imparted to suspended fiber-optic cables by turbulent wastewater flows, predominantly within 10-30 Hz, enabling continuous monitoring along entire river lengths. Vibrational power analysis locates outfalls with meter-level accuracy, while time-frequency techniques discern discharge timing and characteristics. Cable type and outfall-fiber separation influence on detection capability was assessed. Thermoplastic-jacketed tight buffer cables optimized detection through enhanced vibrational coupling. Vibrational energy decreased exponentially with separation, highlighting benefits of proximal deployment for sensitivity. However, detection range scales with discharge flow rate. Frequency centroid proved a robust feature with potential for automated discharge identification. Overall, DAS enables high spatiotemporal resolution monitoring to pinpoint concealed outfalls minimally invasively. This positions DAS as a promising tool supporting improved water governance through early pollution warnings and rapid source localization via outfall vibrational signatures emanating across river networks.


Assuntos
Ecossistema , Águas Residuárias , Rios , Monitoramento Ambiental , Acústica
7.
iScience ; 26(12): 108539, 2023 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-38089574

RESUMO

The analysis of salivary biomarkers as expression of periodontal health conditions has been proposed as a useful aid to conventional diagnostic approaches. In this study, we present a point-of-care test (POCT) exploiting a surface plasmon resonance (SPR)-based optical biosensor to detect salivary macrophage inflammatory protein (MIP)-1α, a promising marker of periodontitis. A plastic optical fiber (POF) was suitably modified and functionalized by an antibody self-assembled monolayer against MIP-1α for plasmonic detection. The proposed SPR-POF biosensor showed high selectivity and very low limit of detection for MIP-1α of 129 fM (1.0 pg/mL) in phosphate-buffered saline and 346 fM (2.7 pg/mL) in saliva. As a proof of concept, this POCT was also able to discriminate between a periodontitis patient and a healthy subject. The obtained results support the future application of this technology for an on-site detection and real-time monitoring of periodontal health conditions for diagnostic and therapeutic purposes.

8.
Sensors (Basel) ; 23(23)2023 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-38067770

RESUMO

For the maintenance of railways on soft soils, accurate knowledge of the subsoil conditions is essential. Soft soils at shallow depths have high variability; thus, high spatial resolution is required. Spare telecommunication fiber-optic cables, known as dark fiber, can be used as an array of sensors to measure waves generated by running trains, which offers a unique opportunity to characterize shallow soils at high spatial resolution. We used dark fiber to measure seismic waves generated by running trains and implemented a seismic interferometry technique to retrieve surface waves. We evaluated the reliability of selected parts of the recorded signals split as bow waves (the train approaching the fiber), train waves (the train passing alongside the fiber), and tail waves (the train leaving the fiber) to retrieve broad-band surface waves. The analysis was performed in two distinctive zones. Zone I consists of a thick-soft (2.0-6.0 m thickness) layer, and Zone II consists of a thin-soft (less than 2.0 m thickness) layer, both overlaying a "stiffer" sand layer. At Zone I, train waves yielded the best results in revealing the thick-soft layer. At Zone II, the bow waves yielded clear high-frequency energy, revealing the overall soil structure but without identifying the shallow thin-soft layer.

9.
J Vasc Surg ; 2023 Nov 04.
Artigo em Inglês | MEDLINE | ID: mdl-37931886

RESUMO

OBJECTIVE: Despite the advantages that fenestrated endovascular aortic repair has over open repair, it is accompanied by the consequence of radiation exposure, which can result in long-term complications for both the patient and surgical staff. Fiber Optic RealShape (FORS) technology is a novel advancement that uses emitted light from a fiber optic wire and enables the surgeon to cannulate vessels in real time without live fluoroscopy. This technology has been implemented at select centers to study its effectiveness for cannulation of target vessels and its impact on procedural radiation. METHODS: We collected prospective data on physician-modified endograft (PMEG) cases before and after the introduction of FORS technology. FORS PMEGs were matched with up to three conventional fluoroscopy cases by number of target vessels, inclusion of a bifurcated device below, aneurysm extent, and patient body mass index. The procedural radiation parameters were compared between these cohorts. Within the FORS cohort, we analyzed the rate of successful target vessel cannulation for all cases done with this technology (including cases other than PMEGs), and we compared the radiation between the cannulations using only FORS with those that abandoned FORS for conventional fluoroscopy. RESULTS: Nineteen FORS PMEGs were able to be matched to 45 conventional fluoroscopy cases. Procedures that used FORS technology had significantly reduced total air kerma (527 mGy vs 964 mGy), dose area product (121 Gy∗cm2 vs 186 Gy∗cm2), fluoroscopy dose (72.1 Gy∗cm2 vs 132.5 Gy∗cm2), and fluoroscopy time (45 minutes vs 72 minutes). There was no difference in procedure length, total contrast, or digital subtraction angiography. Within FORS cases, 66% of cannulations were completed using only FORS. Cannulations using only FORS had significant reduction of navigation air kerma (5.0 mGy vs 26.5 mGy), dose area product (1.2 Gy∗cm2 vs 5.1 Gy∗cm2), and fluoroscopy time (0.6 minutes vs 2.3 minutes) compared with cannulations abandoning FORS for conventional fluoroscopy. CONCLUSIONS: This study demonstrates the advantages of FORS for total procedural radiation as well as during individual cannulation tasks. The implementation of FORS for target vessel catheterization has the potential to decrease the total degree of radiation exposure for the patient and surgical staff during complex endovascular aortic surgeries.

10.
Data Brief ; 51: 109756, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38020435

RESUMO

Braided rivers play a significant role in replenishing groundwater, but our understanding of how these recharge rates fluctuate over time remains limited. Traditional techniques for gauging groundwater recharge are ineffective for studying complex braided river systems due to their insufficient spatiotemporal resolution. To address this gap, active-distributed temperature sensing (A-DTS) was used. This method combines fiber optic temperature measurements with an active heat source, enabling quantification of groundwater fluxes. In this study, twelve consecutive A-DTS surveys were conducted on a 100 m long hybrid fiber optic cable to a depth of 5 m beneath the Waikirikiri Selwyn River. This experiment was conducted during a period of relatively stable river stage and flow, highlighting the effectiveness of using A-DTS to measure temporal changes in groundwater recharge.

11.
Adv Sci (Weinh) ; 10(35): e2303835, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37786262

RESUMO

The performance limitations of traditional computer architectures have led to the rise of brain-inspired hardware, with optical solutions gaining popularity due to the energy efficiency, high speed, and scalability of linear operations. However, the use of optics to emulate the synaptic activity of neurons has remained a challenge since the integration of nonlinear nodes is power-hungry and, thus, hard to scale. Neuromorphic wave computing offers a new paradigm for energy-efficient information processing, building upon transient and passively nonlinear interactions between optical modes in a waveguide. Here, an implementation of this concept is presented using broadband frequency conversion by coherent higher-order soliton fission in a single-mode fiber. It is shown that phase encoding on femtosecond pulses at the input, alongside frequency selection and weighting at the system output, makes transient spectro-temporal system states interpretable and allows for the energy-efficient emulation of various digital neural networks. The experiments in a compact, fully fiber-integrated setup substantiate an anticipated enhancement in computational performance with increasing system nonlinearity. The findings suggest that broadband frequency generation, accessible on-chip and in-fiber with off-the-shelf components, may challenge the traditional approach to node-based brain-inspired hardware design, ultimately leading to energy-efficient, scalable, and dependable computing with minimal optical hardware requirements.

12.
Sensors (Basel) ; 23(18)2023 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-37765826

RESUMO

The properties of the state of polarization (SOP) and the degree of polarization (DOP) of Rayleigh backscattered light (RBL) in single-mode fibers (SMF) are investigated theoretically and experimentally when the incident probe is a perfectly coherent continuous-wave (CW) light. It is concluded that the instantaneous DOP of the coherently superposed RBL is always 100%, and the instantaneous SOP is determined by the distributions of the birefringence and the optical phase along the SMF. Therefore, the instantaneous SOP of the coherently superposed RBL does not have a constant relationship with the SOP of the incident CW probe. Furthermore, the instantaneous SOP varies randomly with time because the optical phase is very sensitive to ambient temperature and vibration even in the lab environment. Further theoretical derivation and experimental verification demonstrate, for the first time, that the temporally averaged SOP of the coherently superposed RBL has a simple constant relationship with the SOP of the incident CW probe, and the temporally averaged DOP is 1/3 in an SMF with low and randomly distributed birefringence. The derived formulas and obtained findings can be used to enhance the modelling and improve the performances of phase-sensitive optical time-domain reflectometry and other Rayleigh backscattering based fiber-optic sensors.

13.
Diagnostics (Basel) ; 13(16)2023 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-37627901

RESUMO

Malignant transformation of oral lichen planus (OLP) into oral squamous cell carcinoma is considered as one of the most serious complications of OLP. For the early detection of oral cancer in OLP follow-up, accurate localization of the OLP center is still difficult but often required for confirmatory biopsy with histopathological examination. Optical coherence tomography (OCT) offers the potential for more reliable biopsy sampling in the oral cavity as it is capable of non-invasively imaging the degenerated oral layer structure. In this case-series study with 15 patients, features of clinically classified forms of OLP in OCT cross-sections were registered and correlated with available histologic sections. Besides patients with reticular, atrophic, erosive and plaque-like OLP, two patients with leukoplakia were included for differentiation. The results show that OCT yields information about the epithelial surface, thickness and reflectivity, as well as the identifiability of the basement membrane and the vessel network, which could be used to complement the visual clinical appearance of OLP variants and allow a more accurate localization of the OLP center. This forms the basis for further studies on OCT-assisted non-invasive clinical classification of OLP, with the aim of enabling decision support for biopsy sampling in the future.

14.
Sensors (Basel) ; 23(16)2023 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-37631810

RESUMO

Turbidity is an important water quality parameter, especially for drinking water. The ability to actively monitor the turbidity level of drinking water distribution systems is of critical importance to the safety and wellbeing of the public. Traditional turbidity monitoring methods involve the manual collection of water samples at set locations and times followed by laboratory analysis, which are labor intensive and time consuming. Fiber-optic measurement permits real-time, in situ turbidity monitoring. But the current technology is based on plastic fibers, which suffer from high optical attenuation and hence are unsuitable for large-scale remote monitoring. In this paper, we report the demonstration of a fiber-optic turbidity sensor based on multi-mode glass fibers. The system uses a single fiber to both deliver laser light into the water sample and collect the back-scattered light for detection. A balanced detection scheme is utilized to remove the common-mode noise to enhance the turbidity sensitivity. Highly linear turbidity responses are obtained and a turbidity resolution as low as 0.1 NTU is achieved. The test unit is also shown to have excellent reproducibility against repeated measurements and good stability against temperature changes. Turbidity measurement in real environmental matrices such as tap water and pond water is also reported with an assessment of the impact of flow rate. This work demonstrates the feasibility of future large-scale distributed fiber-optic turbidity monitoring networks.

15.
iScience ; 26(7): 107244, 2023 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-37496677

RESUMO

The prevalence of sleep disorders has increased because of the fast-paced and stressful modern lifestyle, negatively impacting the quality of human life and work efficiency. It is crucial to address sleep problems. However, the current practice of diagnosing sleep disorders using polysomnography (PSG) has limitations such as complexity, large equipment, and low portability, hindering its practicality for daily use. To overcome these challenges, in this article an optical fiber sensor is proposed as a viable solution for sleep monitoring. This device offers benefits like low power consumption, non-invasiveness, absence of interference, and real-time health monitoring. We introduce the sensor with an optical fiber interferometer to capture ballistocardiography (BCG) and electrocardiogram (ECG) signals from the human body. Furthermore, a new machine learning method is proposed for sleep condition detection. Experimental results demonstrate the superior performance of this architecture and the proposed model in monitoring and assessing sleep quality.

16.
Sensors (Basel) ; 23(13)2023 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-37447811

RESUMO

This work presents a novel methodology for the accurate and efficient elastic deformation reconstruction of thin-walled and stiffened structures from discrete strains. It builds on the inverse finite element method (iFEM), a variationally-based shape-sensing approach that reconstructs structural displacements by matching a set of analytical and experimental strains in a least-squares sense. As iFEM employs the finite element framework to discretize the structural domain and as the displacements and strains are approximated using element shape functions, the kind of element used influences the accuracy and efficiency of the iFEM analysis. This problem is addressed in the present work through a novel discretization scheme that combines beam and shell inverse elements to develop an iFEM model of the structure. Such a hybrid discretization paradigm paves the way for more accurate shape-sensing of geometrically complex structures using fewer sensor measurements and lower computational effort than traditional approaches. The hybrid iFEM is experimentally demonstrated in this work for the shape sensing of bending and torsional deformations of a composite stiffened wing panel instrumented with strain rosettes and fiber-optic sensors. The experimental results are accurate, robust, and computationally efficient, demonstrating the potential of this hybrid scheme for developing an efficient digital twin for online structural monitoring and control.


Assuntos
Tecnologia de Fibra Óptica , Análise de Elementos Finitos
17.
Sensors (Basel) ; 23(14)2023 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-37514584

RESUMO

We report on the fabrication and testing of a fiber optics sensor based on multimodal interference effects, which aims at the detection of different types of sweeteners dissolved in water. The device, which has a simple structure, commonly known as the SMS configuration, is built by splicing a segment of commercial-grade, coreless multimode fiber (NC-MMF) between two standard single-mode fibers (SMFs). In this configuration, the evanescent field traveling outside the core of the NC-MMF allows the sensing of the refractive index of the surrounding media, making it possible to detect different levels of sugar concentration. The optical sensor was tested with aqueous solutions of glucose, fructose, and sucrose in the concentration range from 0 wt% to 20 wt% at room temperature. The proposed device exhibits a linear response with a sensitivity of 0.1835 nm/wt% for sucrose, 0.1687 nm/wt% for fructose, and 0.1694 nm/wt% for glucose, respectively, with a sensing resolution of around 0.5 wt%. Finally, we show that, despite having similar concentration behavior, some degree of discrimination between the different sugars can be achieved by assessing their thermo-optical response.

18.
Sensors (Basel) ; 23(7)2023 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-37050797

RESUMO

Distributed Dynamic Strain Sensing (DDSS), also known as Distributed Acoustic Sensing (DAS), is becoming a popular tool in array seismology. A new generation of engineered fibers is being developed to improve sensitivity and reduce the noise floor in comparison to standard fibers, which are conventionally used in telecommunication networks. Nevertheless, standard fibers already have extensive coverage around the Earth's surface, so it motivates the use of the existing infrastructure in DDSS surveys to avoid costs and logistics. In this study, we compare DDSS data from stack instances of standard multi-fiber cable with DDSS data from a co-located single-fiber engineered cable. Both cables were buried in an area located 2.5 km NE from the craters of Mt. Etna. We analyze how stacking can improve signal quality. Our findings indicate that the stack of DDSS records from five standard fiber instances, each 1.5 km long, can reduce optical noise of up to 20%. We also present an algorithm to correct artifacts in the time series that stem from dynamic range saturation. Although stacking is able to reduce optical noise, it is not sufficient for restoring the strain-rate amplitude from saturated signals in standard fiber DDSS. Nevertheless, the algorithm can restore the strain-rate amplitude from saturated DDSS signals of the engineered fiber, allowing us to exceed the dynamic range of the record. We present measurement strategies to increase the dynamic range and avoid saturation.

19.
Sensors (Basel) ; 23(5)2023 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-36904714

RESUMO

In the upcoming space revolutions aiming at the implementation of automated, smart, and self-aware crewless vehicles and reusable spacecraft, sensors play a significant role in the control systems. In particular, fiber optic sensors, with their small footprint and electromagnetic immunity, represent a great opportunity in aerospace. The radiation environment and the harsh conditions in which these sensors will operate represent a challenge for the potential user in the aerospace vehicle design and the fiber optic sensor specialist. We present a review that aims to be a primer in the field of fiber optic sensors in radiation environments for aerospace. We review the main aerospace requirements and their relationship with fiber optics. We also present a brief overview of fiber optics and sensors based on them. Finally, we present different examples of applications in radiation environments for aerospace applications.

20.
Sensors (Basel) ; 23(6)2023 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-36991622

RESUMO

Diffuse reflectance spectroscopy (DRS) has proven to be a powerful, reliable, and non-invasive optical method for characterizing a specimen. Nevertheless, these methods are based on a rudimentary interpretation of the spectral response and can be irrelevant to understanding 3D structures. In this work, we proposed adding optical modalities into a customized handheld probe head in order to increase the number of parameters in DRS acquired from the light/matter interaction. It consists of (1) placing the sample in a reflectance manual rotation stage to collect spectral backscattered angularly resolved light and (2) illuminating it with two sequential linear polarization orientations. We demonstrate that this innovative approach leads to a compact instrument, capable of performing fast polarization-resolved spectroscopic analysis. Due to the significant amount of data available with this technique in a short time, we observe sensitive quantitative discrimination between two types of biological tissue provided by a raw rabbit leg. We believe that this technique can pave the way for rapid meat quality check or biomedical diagnosis of pathological tissues in situ at an early stage.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...